80 mm
Our best-insulated sectional door
The ISO 80 is the sectional door for the strictest energy requirements. Its 80 mm panels are fully thermally separated: there is insulation between all metal surfaces. With a panel value of 0.25 W/m²K, it is the logical choice for cold stores, distribution centres and halls where heat loss costs money.
- Panel thickness
- 80 mm
- Panel U-value
- 0.25 W/m²K
- Max. size
- 8,000 × 6,000 mm
- Wind resistance
- Class 3–4
Fully thermally separated
On the ISO 80, not only the panels but also the end caps are thermally broken. The sections join wind- and watertight with plastic seals, and the door has a double top seal. A complete 5 × 5 metre door therefore achieves a U-value of 0.49 W/m²K.
At the bottom, a double bottom rubber with inward-curved lips ensures an optimal seal to the floor, even on slightly uneven ground.
Also with ALU panels and windows
Still want daylight? Choose windows with quadruple insulating glazing, or up to three ALU panels (up to 6,000 mm wide). The exterior is micro-profiled in RAL 9002, 9006 or 7016 as standard; other colours are possible.
Specifications 80 mm
Dimensions
- Panel thickness
- 80 mm
- Max. width
- 8,000 mm
- Max. height
- 6,000 mm
- Max. area
- 42 m²
- Extra side room
- 2 × 12.5 mm
Performance
- Panel U-value
- 0.25 W/m²K
- Door U-value (5 × 5 m, closed)
- 0.49 W/m²K
- Wind resistance
- Class 3–4 (EN 12424), up to 12–13 Beaufort
Panels & finish
- Panel
- Thermally separated galvanised steel with PUR foam (40 kg/m³, CFC-free)
- End caps
- Thermally broken, galvanised steel
- Sealing
- Multiple rubber top, side and bottom seals, foam between panels
- Exterior
- Micro-profiled in RAL 9002, 9006 or 7016
- Interior
- Stucco, horizontally profiled, RAL 9002
- Windows
- Quadruple insulating glazing
Construction
- Track systems
- T400, T450, T500 and HF versions
- Tracks
- Sendzimir galvanised steel
- Rollers
- Nylon tread, 11 mm axle
- Steel cables
- Six-fold safety factor
Drive & control
- Operation
- Manual (pull rope or chain hoist) or electric
- Control
- Hold-to-run, impulse or remote control
- Control units
- TS971, TS981 or T100R (frequency-controlled)
- Motor supply voltage
- 230 V or 400 V, 50/60 Hz
- Motor protection class
- IP54
- Connectable
- Push button, pull switch, key switch, photocell, radar, induction loop, hand transmitter
- Smart control
- Force monitoring, cycle counter and fault memory (last 6 messages)
Safety
- Spring break protection
- Standard
- Slack cable protection
- Standard
- Emergency operation
- Hand chain down to operating height
- Standard
- EN 13241
- Opto sensors
- Double as standard
All values are indicative and depend on the configuration. Subject to technical changes.


