ISO 60 mm
The ISO 60 is the sectional door for places where a constant temperature matters. Its 60 mm thermally separated panels insulate significantly better than a standard door and effectively separate warm and cold zones – think production halls, storage and temperature-sensitive goods.
- Panel thickness
- 60 mm
- Door U-value
- 0.84 W/m²K
- Max. size
- 8,000 × 6,000 mm
- Standard colours
- 14 RAL
More insulation, same ease of use
Each panel consists of two galvanised steel sheets with polyurethane foam and a thermal break in between. As a result, the panel achieves a U-value of 0.35 W/m²K and a complete 5 × 5 metre door 0.84 W/m²K. That makes a noticeable difference to your heating bill.
The panels are also excellent at dampening sound and highly weather-resistant. The exterior has the same crisp micro-profiling as the ISO 40 and is available in 14 standard colours.
With windows, ALU sections or wicket door
Choose rectangular windows with double-walled glazing, or complete aluminium sections with double or triple glazing. An integrated wicket door is also possible on the ISO 60.
Specifications ISO 60 mm
Dimensions
- Panel thickness
- 60 mm
- Max. width
- 8,000 mm
- Max. height
- 6,000 mm
- Max. area
- 48 m²
Performance
- Panel U-value
- 0.35 W/m²K
- Door U-value (5 × 5 m, closed)
- 0.84 W/m²K
- Wind resistance
- Class 3–4 (EN 12424), up to 12–13 Beaufort
Panels & finish
- Panel
- Thermally separated galvanised steel with PUR foam (CFC-free)
- Exterior
- Micro-profiled, polyester coating
- Interior
- Horizontally profiled, RAL 9002
- Standard colours
- RAL 3000, 5010, 6005, 6009, 7005, 7015, 7016, 7022, 7035, 8014, 9002, 9006, 9007, 9010
- End caps
- Galvanised steel
Construction
- Tracks
- Sendzimir galvanised steel
- Rollers
- Nylon tread, 11 mm axle
- Steel cables
- Six-fold safety factor
- Hardware
- Galvanised
- Sealing
- EPDM all round and between sections
- Lift types
- Standard, high, vertical, roof-pitch or low headroom
Drive & control
- Operation
- Manual (pull rope or chain hoist) or electric
- Control
- Hold-to-run, impulse or remote control
- Control units
- TS971, TS981 or T100R (frequency-controlled)
- Motor supply voltage
- 230 V or 400 V, 50/60 Hz
- Motor protection class
- IP54
- Connectable
- Push button, pull switch, key switch, photocell, radar, induction loop, hand transmitter
- Smart control
- Force monitoring, cycle counter and fault memory (last 6 messages)
Safety
- Spring break protection
- Standard
- Slack cable protection
- Standard
- Emergency operation
- Hand chain down to operating height
- Standard
- EN 13241