ALU 60 mm
The ALU 60 combines plenty of daylight with good insulation. Each aluminium profile consists of two halves thermally separated by plastic insulating profiles. That leaves no chance for condensation on the inside and keeps the indoor climate stable.
- Profile thickness
- 60 mm
- Door U-value
- 2.38 W/m²K
- Max. size
- 8,000 × 6,000 mm
- Glazing
- Triple
A glass door without condensation
On a standard aluminium door, condensation can form on the profiles in the colder months. The ALU 60 is one and a half times as thick as the ALU 40 and comes with triple glazing as standard. It therefore insulates better, dampens more noise and keeps the inside dry.
Ideal for spaces where light, visibility and a constant indoor climate matter, such as workshops, showrooms and heated halls.
Freely configurable
The sections can be filled with various types of glass and plastic or with solid, double-walled sandwich panels. The ALU 60 is also available with an integrated wicket door.
Specifications ALU 60 mm
Dimensions
- Profile thickness
- 60 mm
- Max. width
- 8,000 mm
- Max. height
- 6,000 mm
- Max. area
- 48 m²
Performance
- U-value (5 × 5 m, triple glazing)
- 2.38 W/m²K
- Wind resistance
- Class 3–4 (EN 12424), up to 12–13 Beaufort
- Condensation
- Thermally separated profiles prevent condensation
Materials & infills
- Frame
- Anodised aluminium profiles, thermally separated by plastic insulating profiles
- Glazing
- Triple as standard
- Infills
- Various types of glass and plastic or double-walled sandwich infill
- Frame colour
- Anodised, colour coating optional
Construction
- Tracks
- Sendzimir galvanised steel
- Rollers
- Nylon tread, 11 mm axle
- Steel cables
- Six-fold safety factor
- Hardware
- Galvanised
- Sealing
- EPDM all round and between sections
- Lift types
- Standard, high, vertical, roof-pitch or low headroom
Drive & control
- Operation
- Manual (pull rope or chain hoist) or electric
- Control
- Hold-to-run, impulse or remote control
- Control units
- TS971, TS981 or T100R (frequency-controlled)
- Motor supply voltage
- 230 V or 400 V, 50/60 Hz
- Motor protection class
- IP54
- Connectable
- Push button, pull switch, key switch, photocell, radar, induction loop, hand transmitter
- Smart control
- Force monitoring, cycle counter and fault memory (last 6 messages)
Safety
- Spring break protection
- Standard
- Slack cable protection
- Standard
- Emergency operation
- Hand chain down to operating height
- Standard
- EN 13241
All values are indicative and depend on the configuration. Subject to technical changes.